4.1.3

IDE: SRST

This history entry is recorded when a software reset is detected. If this history entry does
not appear even after the main CPU has issued a software reset, there may be a problem
with signal quality or in the signal connections shown below.
• CS1-, DA0 to DA2, DD0 to DD7, DIOW-
4.1.4

IDE: command [xxh]

This history entry is recorded when a command is received. The [xxh] part indicates the
command code for ATA commands and the operation code for ATAPI commands. If this
history entry does not appear even after the main CPU has issued a command or if the
command issued by the IDE host does not match the command/operation code in the
history, there may be a problem with signal quality or in the signal connections shown
below.
• CS0-, CS1-, DA0 to DA2, DD0 to DD7, DIOW-
4.1.5
IDE: PIO (D->H)
This history entry is recorded when PIO format data transfer starts. If "IDE: INTRQ" or
"IDE: idle" does not appear after the history entry, there may be a problem with signal
quality or in the signal connections shown below.
• CS0-, CS1-, DA0 to DA2, DIOW-, DIOR-
If data is incorrect, there may be a problem with signal quality or in the signal connections
shown below.
• DD0 to DD15
4.1.6
IDE: PIO (H->D)
Refer to "4.1.5 IDE: PIO (D->H)".
4.1.7
IDE: Multi Word DMA (D->H)
This history entry is recorded when Multi Word DMA format data transfer starts. If "IDE:
INTRQ" does not appear after the history entry, there may be a problem with signal quality
or in the signal connections shown below.
• DIOW-, DIOR-, DMARQ, DMACK -
If data is incorrect, there may be a problem with signal quality or in the signal connections
shown below.
• DD0 to DD15