1010music Toolbox v 1.1.4 User Manual page 21

Table of Contents

Advertisement

1.
Start by plugging a CV signal source into input CV 1, CV 2, or both to record in stereo. These are the inputs
on the edge of the module near the Clock input.
2.
Press HOME until you get to the
3.
Touch a cell that is mapped to a CV Output jack to open it.
4.
Change the Cell Type to CREC by touching the Cell Type button next to the grid icon
in the top row of the parameters screen, and then selecting
Types. You will now see the CREC Load and Record screen.
5.
In the top menu, touch the menu item between the Cell Type button and the
button (
in the example screenshot). This will display the list of input choices.
In 1/2
Touch one of the options to choose whether to record just from In 1, just from In 2, or
from both inputs in stereo.
6.
Before you start recording, set up the parameters that control the recording:
Parameter
Description
Length
This parameter allows you to specify a length of
time that you want to record, in terms of notes
and bars.
When Custom is selected, the module will
continue recording until you touch
Rec Quant
This parameter allows you to quantize the
recording to start and stop at the designated
musical time interval.
When a value other than None is selected, there
may appear to be a lag to when recording starts
and stops. This is because the recording will wait
to start or stop in synch with the selected
quantization setting.
Rec Mon
Controls whether the input signals received
through CV 1 and CV 2 are played out through the
CV output jack to enable you to monitor the
recording. If
the monitoring signal combines the two inputs
into a mono output. However, the recording is in
stereo. Read about the CPLY and OUT cell types
to learn more about stereo playback.
7.
Send a signal to the selected input or inputs. The source will play through the corresponding output jack if
the
setting is
Rec Mon
levels of each of the selected input signals. For best results leave some room (a few dB) between your
loudest level and the max allowed, which is 0dB. If a red bar appears to the right of the level, the signal is
clipping and the level of the input signal should be lowered for best quality.
1.
Touch the
button. Toolbox will start recording. If you selected a time value for
Rec
stop after the selected length of time. The Load and Record screen displays a running clock of measures
and beats and time duration of the recording. There may be a delay between when you touch
when the recording starts as toolbox waits to quantize the recording to the selected
interval. See
6/13/18 7:54 PM
screen.
Main
STOP
is selected as input, then
IN 1/2
or
. The lower left quadrant of the Load and Record screen displays the
ON
Auto
Digital Heart – Analog Soul
from the list of Cell
CREC
Range of Values
,
Custom
¼, ½, 1 bar, 2 bars, 4
bars, 8 bars, 16 bars, 32 bars,
64 bars, 128 bars
.
- always start and stop immediately
None
- quantize to the next sixteenth note
1/16
time
- eighth note
1/8
- quarter note
1/4
- half note
1/2
- a whole note assuming 4/4 time
1 bar
2 bars
4 bars
8 bars
- Inputs are never played through the
Off
outputs.
- Inputs play through the outputs while
Auto
recording or the recording screen is visible.
- Inputs always play through the outputs.
On
Toolbox User Manual
Load
Figure 2 0: CR EC Lo ad
a nd R ecord Screen
, recording will
Length
and
Rec
time
Rec Quant
P. 21
Copyright 1010music LLC 2017

Advertisement