Mitsubishi Electric 800 Series Instruction Manual page 24

Rs-485 interface board, rs-485 communication terminals
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Pr.550
Pr.551
setting
setting
PU connector
1
2
PU operation mode
9999
(initial
value)
3
9999
PU operation
(initial
mode

value)

The MODBUS RTU protocol cannot be used in the PU operation mode. To use the MODBUS RTU protocol, set Pr.551="2".

If the communication option is not mounted, switching to the Network operation mode is not longer possible.

When Pr.551= "9999", the priority of the PU command source is USB connector > PU connector.
Command source
USB connector
RS-485 terminals
PU operation
mode

NET operation
mode
PU operation mode
NET operation
mode
PU operation
mode

NET operation
mode
Remarks
Communication
option
NET operation
mode

NET operation
With communication
mode
option

Without communication
option
NET operation
With communication
mode
option

Without communication
option
NET operation
With communication
mode
option

Without communication
option
PARAMETER
4
23