<Operation mode/inverter setting>
Mode
Read value
EXT
H0000
PU
H0001
EXT
H0002
JOG
PU
H0003
JOG
NET
H0004
PU+EXT
H0005
Enable/disable parameter writing by Pr.79 and Pr.340 settings. For the details, refer to the Instruction Manual (Detailed) of the inverter.
Restrictions in each operation mode conform with the computer link specification.
• Real-time monitor
Refer to the Instruction Manual (Detailed) of the inverter for the register numbers and monitored items of the real time
monitor.
• Parameters
Pr.
Register
For details on parameter names, refer to the
41000 to
0 to 999
parameter list (the Instruction Manual
41999
(Detailed) of the inverter
C2 (902)
41902
Terminal 2 frequency setting bias frequency
Terminal 2 frequency setting bias (analog
42092
value)
C3 (902)
Terminal 2 frequency setting bias (terminal
43902
analog value)
Terminal 2 frequency setting gain frequency
125 (903)
41903
(frequency)
80
PARAMETER
Write value
H0010
H0011
―
―
H0014
―
Name
).
Read/write
The parameter number + 41000 is the register
Read/Write
number.
Read/Write
Read/Write
Analog value (%) set to C3 (902)
Analog value (%) of voltage (current) applied to
Read
terminal 2
Read/Write
Remarks