3. INVERTER CLEANING AND MAINTENANCE

3.1 Introduction

The appearance of the inverter overheated alarm can be caused by the accumulation of dirt and lint at the
inverter cooling area, making it difficult to properly ventilate the equipment. For this reason it is essential to
periodically clean the inverter to maintain good ventilation and thus avoid the overheating problems.
The maintenance and cleaning manual is aimed at HS-6/EH machines with Fuji inverter.

3.2 Preparation

NECESSARY TOOLS
Intervention on HS-6023, HS-6024, EH055, EH060 models
Screwdriver Torx T25
Philips PH-2x125 Screwdriver
Allen wrench 0.12 inch (3 mm)
A soft brush and a dry cloth
Intervention on RMS/RMG628, REM/RMG070 models
Ratchet wrench with socket 5/16 inch (8 mm)
Ratchet wrench with socket 3/8 inch (10 mm)
Screwdriver Torx T25
Philips PH-2x125 Screwdriver
Allen wrench 0.12 inch (3 mm)
A soft brush and a dry cloth
Intervention on HS-6040, HS-6057, EH090, EH130 models
Open end wrench 7/16 inch (10 mm)
Screwdriver Torx T25
Philips PH-2x125 Screwdriver (#2x5 inch)
Philips PH-3x150 Screwdriver (#2x6 inch)
Allen wrench 0.2 inch (5 mm)
A soft brush and a dry cloth
Intervention on HS-6110, EH255 models
Ratchet wrench with socket 3/8 inch (10 mm)
Screwdriver Torx T25
Philips PH-2x125 Screwdriver (#2x5 inch)
Philips PH-3x150 Screwdriver (#2x6 inch)
Screwdriver for slotted-head screws 0.5x3x75
A soft brush and a dry cloth
SAT – Electric Maintenance