(91) Receive pointer and path layer event status register (SPPER)
This register indicates the current status of each event.
Register
Name
Port0:
SPPER
0230 H
31
30
29
28
15
14
13
12
Reserved
Bit
Field
D31-D11
Reserved
Reserved
PTIU
D10
1: Path TIU event in progress
PTIM
D9
1: Path TIM event in progress
PPLU
D8
1: Path PLU event in progress
PUNEQ
D7
1: Path UNEQ event in progress
D6
PPLM
1: Path PLM event in progress
ERDIP
D5
1: Enhanced Path RDI Payload defect event in progress
0: Enhanced Path RDI Payload defect event is not detected.
D4
ERDIC
1: Enhanced Path RDI Connectivity defect event in progress
0: Enhanced Path RDI Connectivity defect event is not detected.
D3
ERDIS
1: Enhanced Path RDI Server defect event in progress
0: Enhanced Path RDI Server defect event is not detected.
OPRDI
D2
1: One-bit Path RDI event in progress
detected.
PAIS
D1
1: Path AIS event in progress
LOP
D0
1: LOP event in progress
258
CHAPTER 5 REGISTERS
Address
Port1:
Port2:
Port3:
0630 H
0A30 H
0E30 H
27
26
25
24
Reserved
11
10
9
8
PTIU
PTIM
PPLU
PRELIMINARY
Access
Default
R
00000002 H
23
22
21
20
7
6
5
4
PUNEQ
PPLM
ERDIP
ERDIC
Function
0: Path TIU event is not detected.
0: Path TIM event is not detected.
0: Path PLU event is not detected.
0: Path UNEQ event is not detected.
0: Path PLM event is not detected.
0: One-bit Path RDI event is not
0: Path AIS event is not detected.
0: LOP event is not detected.
NEC confidential and Proprietary
Function
Read-only
19
18
17
16
3
2
1
0
ERDIS
OPRDI
PAIS
LOP
Default
All 0
0
0
0
0
0
0
0
0
0
1
0