(44) Bit error rate monitoring mode register (MDBER)
The MDBER register sets the monitoring bytes of the bit error rate monitoring function.
Register
Name
Port0:
MDBER
00E0 H
31
30
29
28
15
14
13
12
Reserved
Bit
Field
D31-
Reserved
Set to 0.
D10
D9-D8
SDM[1:0]
Selects the source and enable which SD condition of the bit error rate monitoring is
detected.
11: B3 errors
D7-D2
Reserved
Set to 0.
D1-D0
SFM[1:0]
Selects the source and enable which SF condition of the bit error rate monitoring is
detected.
11: B3 errors
CHAPTER 5 REGISTERS
Address
Port1:
Port2:
Port3:
04E0 H
08E0 H
0CE0 H
27
26
25
24
Reserved
11
10
9
8
SDM[1:0]
10: B2 errors
01: B1 errors
10: B2 errors
01: B1 errors
PRELIMINARY
Access
Default
R/W
00000202 H
23
22
21
20
7
6
5
4
Reserved
Function
00: Disable
00: Disable
19
18
17
16
3
2
1
0
SFM[1:0]
Default
0
10
0
10
NEC confidential and Proprietary