In SLMP scanner

SLMP protocol is used for SLMP scanner communication.
Device values in a programmable controller can be read and written from a vision sensor.
A vision sensor and programmable controller synchronize with a poll interval set in the SLMP scanner setting of In-Sight
Explorer.
This section shows the procedure for connecting with SLMP scanner to input and out data in the following configuration.
• MELSEC iQ-R series programmable controller
• GX Works3
• Vision sensor VS70
• In-Sight Explorer
Connecting SLMP scanner
Operating procedure
1.
Select [Parameter]  "(module name)"  [Module Parameter] in the "Navigation" window of GX Works3, and set the
following items in [Basic Settings]  [Own Node Settings].
• IP Address
• Enable/Disable Online Change: "Enable All (SLMP)"
• External Device Configuration: "<Detailed Settings>"
*1 Click the [Detect Now] button to configure the settings.
2.
Write the parameters to a programmable controller.
2 BASIC OPERATIONS FOR SPREADSHEET
50