4.
Set the following items in GX Works3.
● Set a module parameter.
Select [Parameter] "(module name)" [Module Parameter] in the "Navigation" window, and set the following items in
[Basic Settings] [CC-Link IEF Basic Settings].
• IP address
• To Use or Not to Use CC-Link IEF Basic Setting: Enable
● Configure the CC-Link IEF Basic configuration.
Select [Parameter] "(module name)" [Module Parameter] in the "Navigation" window, and set the following items in
[Basic Settings] [CC-Link IEF Basic Settings] "Network Configuration Settings" "<Detailed Setting>".
Click the [Detect Now] button to configure the settings.
For details on the automatic detection function of connected devices, refer to the following manual.
iQ Sensor Solution Reference Manual
2 BASIC OPERATIONS FOR SPREADSHEET
42
2.8 Establishing Communication