Sony PMW-1000 Service Manual page 144

Memory recorder
Hide thumbs Also See for PMW-1000:
Table of Contents

Advertisement

3.
Set the ITEM-713 to ITEM-718 in the setup extended menu as follows.
Item
713:VIDEO SETUP REFERENCE
715: VIDEO GAIN CONTROL
716: CHROMA GAIN CONTROL
717: CHROMA PHASE CONTROL
718: SETUP LEVEL
Composite Video Output Adjustment (59.94 Hz Mode)
1.
Set as follows in the setup menu.
(Refer to the operation manual.)
Setup menu
ITEM-013 (SYSTEM FREQUENCY SELECT MENU)
ITEM-930 (DOWN CONVERTER MODE)
Preparation
1.
Connecting the analog composite waveform monitor
Connect the analog composite waveform monitor to COMPOSITE OUTPUT 1 connector of the unit as follows.
PMW
1
COMPOSITE
OUTPUT
2
2.
Checking the equipment has warmed up
Before starting the measurement, supply power to this unit and the equipment in use for at least 30 minutes to
warm them up.
Output Level Adjustment
Output channel
COMPOSITE OUTPUT 1
A
1.
Set "F1 : INT SG" on the P1 INPUT page of the function menu to ON to change to SG from HD SDI. (Default:
75% color bars)
PMW-1000
Sub-item
OUTPUT LEVEL
Composite
waveform monitor
75 Ω
Adjustment point (A20 : VPR VR)
VIDEO OUT LEVEL
Setting at adjust-
Customer setting
ment
0.0 %
0
0
0
0
Mode
59.94 Hz
SQUEEZE
Specification
A = 100 ±1 IRE (A = 714 ±7 mV)
7-8