Problem
Drive is not functioning.
Drive is running in the
wrong direction.
Automatic drive com-
mands are not ex-
ecuted.
The set sun and wind
parameters cannot be
changed/displayed.
Sun protection does not
travel to end position.
Wind alarm is displayed
even though there is no
wind.
Automatic drive com-
mands are not ex-
ecuted.
60 - en
What to do if...?
Cause
Incorrect connection.
Incorrect connection
The slide switch is set to
Manual mode.
No sensor connected or
the connecting cable is
faulty.
The running time is too
short.
End position not set.
Cable break
Wind gusts
The automatic sun pro-
tection function was in-
terrupted by a manual
action, such as actu-
ation of the Up/Stop/
Down button.
Remedy
Check connection.
Swap over wire
wire
on the power
supply unit.
Set the slide switch to
Automatic mode.
Check the sensor, con-
necting cable and con-
necting plug.
Adjust the running time
in the Function menu.
Set the end position in
the settings menu SUN
END POSITION or TIME
END POSITION.
Check the cable, re-
place if necessary.
Wait approx.15
minutes.
Move the slide switch
from position "
" into
position " " and back
to position "
".
and