1.
Open/close the sun protection to the intermediate position II.
2.
Simultaneously press and hold the STOP button and the retract button.
3.
The sun protection shifts to confirm.
4.
The intermediate position II is now deleted.

Deleting the intermediate positions

Press the STOP button twice within 0.5 seconds and then press and hold for
10 seconds.
The sun protection shifts to confirm.
All stored intermediate positions are now deleted.
Rated voltage
Switching current
Battery type
Degree of protection
Class of protection
(dependent on correct assembly)
Permissible ambient temperature
Type of mounting
58 - en

Technical data

230 V AC / 50 Hz
5 A /250 V AC at cos
CR 2032
IP 20
II
0 to +55 °C
Flush mounted Ø 58 mm, wall moun-
ted/surface mounted in appropriate
surface mounted housing
=1