Type
Operating voltage (U
)
b
Voltage drop at switching
output
Current at switching output max. 130 mA
Induced current
consumption
Switching delay
Electrical connection
Short circuit reaction
Electromagnetic
compatibility
Vibration resistance
Schock resistance
Protection class
Materials
Fig. 25
9701a
PENV-PS/O-S-L-GH
PENV-NS/O-S-L-GH
DC 10 ... 30 V, rated value DC 24 V (superimposed AC share up to 10% of U
max. 1.2 V
max. 25 mA
max. 5 ms
Protected against incorrect polarity
in cycle (as per VDE 160)
Immunity to interference as per DIN EN 50 082-2
The following minimum operating quality is guaranted when there is interference from electromagnetic HF-
fields as per ENV 50 140 and ENV 50 141:
The switching point can be modified by max. ± 0.3 bar (VPENV-...) or ± 3 bar (PENV-...).
Interference emission as per DIN EN 50 081-1
max. 15 g as per IEC 68-2-6 (no influencing of function)
max. 30 g/11 ms as per IEC 68-2-27 (no influencing of function)
IP 65 nach IEC 529 with cover screwed on
Housing:
PA, PET, PC, NBR
Pressure chamber:
PEI, silicium
Plugs:
CuZn, chromium-plated
Screws:
Ms, nickel-plated
VPENV-PS/O-S-L-GH
VPENV-NS/O-S-L-GH
permitted)
b
D/GB 19