Idle Speed - KYMCO K-XCT 125i Service Manual

Table of Contents

Advertisement

3
. INSPECTION/ADJUSTMENT
Adjust by loosening the valve adjusting screw
lock-nut and turning the adjusting screw
until there is a slight drag on the thickness
gauge .
Valve Clearance: IN: 0.1 mm
Apply oil to the valve adjusting screw
lock-nut threads and seating surface.
Hold the adjusting screw and tighten the lock
nut to the specified torque.
Torque: 0.9 kgf-m (9 N-m)
Special tool:
Valve adjuster
After tightening the lock-nut, recheck the
valve clearance.
Install the removed parts in the reverse order
of removal.

IDLE SPEED

● It is not necessary to adjust idle speed.
The throttle body is factory preset
originally, do not loosen or tighten the
painted bolts and screws of throttle
body. Loosening or tightening them can
cause throttle a idle and valve with
failure.
Warm up the engine before this operation.
Start the engine and connect a tachometer.
Turn the throttle stop screw (1) to obtain the
specified idle speed.
Idle Speed:
DINK 125: 1700 rpm
1800 rpm
When the engine misses or run erratic, adjust
the pilot screw (2).
3-15
EX:0.1 mm
A120E00036
K-XCT 125i