ZyXEL Communications Omni 56K II User Manual page 69

Voice/fax/data modem
Hide thumbs Also See for Omni 56K II:
Table of Contents

Advertisement

COMMAND
FUNCTION
+VRA
Ring back goes away
timer
+VRN
Ring back never
come timer
+VTX
Voice transmit mode
+VSD
Silence detection
+VSM
Selection of
compression method
+VTS= [x,y,z]
Dual Tone
Generation
+VTS= {x,y}
DTMF Tone
Generation
+VTS= x,x...
DTMF Tone
Generation
Command Sets
Omni 56K II and Omni 56K Plus II User's Guide
OPTION
DEFAULT
0 - 255
70
0 - 255
10
N/A
N/A
Threshold,
15,70
Period (0-
255), (0-
255)
4;ZyXEL
4,9600
ADPCM; 4
Bit;(9600)
x: 0-3000
N/A
Hz
y: 0-3000
Hz
z: 0-
1000(10ms)
x:0-9,*,#, A-
N/A
D y:0-1000
(10ms)
x:0-9,*,#, A-
N/A
D
DESCRIPTION
2: The DCE is off-hook and is
connected to the telephone line.
Power is also provided to the local
phone. The modem is able to
record/play through the local
telephone line.
0 : turns off the timer
1-255: Defines the period without
ringback (after at least one ringback
has been detected) in 100 -ms units.
0 : turns off the timer
1-255: Defines the period without
ringback after dialing in 1 sec units.
Switches to voice transmit mode.
Threshold:
0: Disable silence detection.
1-255: The smaller the value, the more
sensitive to the silence detection it will
be.
Period:
1-255: The required period of silence
detection before DCE reports the
silence event.
0: Disable silence detection.
Unit: 0.1 second
IMA 4 bit ADPCM.
Sample rate : 9600
x: first tone frequency
y: second tone frequency
z: duration in 10ms unit
x: DTMF digits (0-9,*,#, A,B,C,D)
y: duration in 10ms unit
x: DTMF digits (0-9,*,#, A,B,C,D)
Duration:+VTD setting. (in 10ms unit)
5-23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omni 56k ii, 56k plus iiOmni 56k plus ii,

Table of Contents