THE MODEMS LISTED BELOW HAVE BEEN TESTED AND FOUND TO WORK SATISFACTORILY WITH GALAXY GOLD
Manufacturer
Type/Model
3Com
3CCM156UK (PCMCIA)
Megahertz 56K Global Modem PC Card
Dataflex Design Limited
Internal Super Gem (Product Code IM93)
Digicom
K56 Flex
Hayes
Accura 288 V.34 and Fax – External
Hayes
Accura 336 Message Modem – External
Hayes
Smart Modem Model 07:00038 – External
Hayes
Smart Modem Optima 288 V.FC and Fax – External
Hayes
Accura 56k Speakerphone Modem
Hayes
Accura V92 15328 Series 0269
Hayes
Accura 56k 15400 Series 0269
Lasat
Lasat Credit 336 – PCMCIA
MR Modem
PCMCIA 56K
Multi-Tech System Inc
MT2834ZDX – External
Multi-Tech System Inc
56K MT5600ZDXV – External
Pace
PACE Linnet 34 fx
Psion
Gold Card PCMCIA
(Advised by customer - not confirmed)
Trio
Trio Fax/Data Modem Model FB1428VQE-T (V.34)
US Robotics
Sportster Vi 14.4 Faxmodem with Voice Mail
US Robotics
5630B Fax Modem 56K V92
US Robotics
5668B message Modem 56K V92
Zoom
56K Dual Mode Modem – External (2956L or 3094L)
Zoom
3090 Mini USB 56K
Zoom
56K 3049C
The Galaxy Gold and Event Monitoring default Modem Reset String is: B0X2V0L3E0S12=20S0=0S7=60
* For modems with the Conexant Chipset, at least V6.8 Galaxy Gold and V3.8 Event Monitoring are required. Earlier versions of Galaxy Gold and Event Monitoring will not work with
these modems.
Appendix F :
Galaxy Gold Modem Reset Strings
There is no Guarantee that every combination of Modem and PC will work
Comments
B0X2V0L3E0S12=20S0=0S7=60
F4W0 B0X2V0L3E0S12=20S0=0S7=60
F4 forces the modem to 1200 Baud (CCITT V.22)
W0 forces the modem to only report DTE speed
To the beginning of the default Modem Reset String add: X3+MS=2, 1, 1200, 2400
B0X2V0L3E0S12=20S0=0S7=60
B0X2V0L3E0S12=20S0=0S7=60
B0X2V0L3E0S12=20S0=0S7=60
B0X2V0L3E0S12=20S0=0S7=60
B0X2V0L3E0S12=20S0=0S7=50S37=5
B0X2V0L3E0S12=20S0=0S7=60+MS=V22
B0X2V0L3E0S12=20S0=0S7=60+MS=V22
B0E0L2&G0W0
B0X3V0L3E0S12=20S0=0S7=60S37=5
B0X2V0L3E0S12=20S0=0S7=60
X3+MS=2, 1, 1200, 2400B0X2V0L3E0S12=20S0=0S7=60
+MS=1,0,1200,1200B0X2V0L3E0S12=20S0=0S7=60
B0X2V0L3E0S12=20S0=0S7=60S37=011110
B0X3V0L3E0S12=20S0=0S7=60
B0X2V0L3E0S12=20S0=0S7=60
B0X2V0L3E0S12=20S0=0S7=60
B0X2V0L3E0S12=20S0=0S7=60
B0X2V0L3E0S12=20S0=0S7=60S37=5
B0X2V0L3E0S12=20S0=0S7=60
X2V0L3E0S12=20S0=0S7=60+MS=V22
(Adding S37=5 helps with some modems)
Page 71
PC
Panel
*V6.8/3.8 are required
*V6.8/3.8 are required
*V6.8/3.8 are required
Call Back
V21
X
X
X