A n t i c i pa t o r & Fo l l o w e r
Anticipator and Follower time are used with air atomizing spray nozzles such as the 1/4JAU Automatic air atomizing spray
nozzle from Spraying Systems Co. These times allow you to adjust the time of actuation of the atomizing air. They help
minimize the spitting that can occur at the beginning or end of a spray cycle. Anticipator is the time the atomizing air will
spray prior to the spray period or liquid being spray from the nozzle.
Follower time is the length of time the atomizing air will continue to spray after the spray period has elapsed or time after
liquid has stopped spraying from the nozzle.
M a x. F r e qu enc y
The maximum frequency setting is used with electric actuated spray nozzle.
25
Need help?
Do you have a question about the 1550+ AutoJet and is the answer not in the manual?