Promac SY-350V Operating Instructions Manual page 10

Metal cold saw
Table of Contents

Advertisement

Available languages

Available languages

Install the splash plates:
Insert a splash plate (1E) onto the front sidewall of
machine base.
Align the 2 slots (1F) in the base of the splash plate with
the matching screw holes on the machine base.
Apply a washer for each of 2 hex socket head screws
M8x20.
Loosely screw the socket hex head screws into the
aligned slot (1F) and holes.
Adjust the splash plate (1E) to the proper position and
tighten down the screws to secure.
Insert a longer one of splash plate (1G) onto the rear
sidewall of the machine base. This plate need not be
secured with screws to allow free movement or
convenient removal.
6.4 Electrical connection of the machine
The machine is equiped with a CCE-16A plug. Make sure to
connect to voltage ~400V, 3phase.
The control electrical box is located at the front of the stand
with a latching door.
The power connection cable is at the rear of the electrical
box as shown in the picture (6.4 -1).
This machine uses an inverter to change the speed rate from
24~120rpm. Please refer to the information in front of the
window on the control panel.
If the machine cannot be operated after wires have been
connected, please check the following items:
1. The Emergency switch is released.
2. The door of the electrical cabinet is properly closed
and switched ON (locked).
3. Refer to the Table of Error Codes for the inverter ( 8.6)