CONTROL PANEL
There are three indicator lights and two key on the front control panel. The lights is for providing status
information of the machine. The left key is for manual water clean function, the other key is for timer reset of air
filter routine maintenance alarms for cleaning.
Running Status
Cleaning
Ice Making
Ice Full
Condenser Cleaning
Alarm
Error Status
Condenser Sensor
Error
Evaporator Sensor
Error
Water Shortage
High Pressure
Bin Full Sensor Error
Temperature Error
Water Level Error
Harvest Overtime
Ice Making Overtime
ICE THICKNESS ADJUSTMENT
Observe the first ice cube harvest and check size of the ice cubes; if an adjustment is necessary, turn the
adjustment screw clockwise to increase ice thickness, counterclockwise to decrease ice thickness. Every 1/3
circle turn will increases or decrease 1.5mm as shown as below illustration.
Power Light
On
On
Off
Flashing and Beeping
Power Light
*
*
One Flash
One Beep
Two Flashes
Two Beeps
Three Flashes
Three Beeps
Four Flashes
Four Beeps
Five Flashes
Five Beeps
Six Flashes
Six Beeps
Seven Flashes
Seven Beeps
11
Ice-Making Light
Flashing
On
Off
Flashing and Beeping
Ice-Making Light
*
Flashing
*
*
*
*
*
*
*

Operation

Ice Full Light
Flashing
Off
On
Flashing and Beeping
Ice Full Light
Flashing
*
*
*
*
*
*
*
*