GEM R563 Operating Instructions Manual page 25

Motorized control valve
Hide thumbs Also See for R563:
Table of Contents

Advertisement

In-
Sub-
Access
dex
In-
rights
dex
2
R/W
0x50
1
R/W
2
R/W
3
R/W
4
R/W
0x51
1
R/W
2
R/W
3
RO
4
RO
0x53
1
RO
2
RO
3
RO
0x55
1
RO
2
RO
0x60
1
RO
2
RO
3
RO
4
RO
0x62
1
RO
2
RO
0x90
2
R/W
3
R/W
www.gemu-group.com
Index name
Basic settings
Inversion of LED
On site initialization Activate / deactiv-
Operating mode
IO-Link process
Actuator position
feedback
Close request
Initialized positions
Calibrated positions
Analog values
Potentiometer
Supply voltage
Operating times
Drive sets
Force initialization
Parameter
Function
Error time
Determine time
from error detec-
tion to error mes-
Activate / deactiv-
colours
ate inversion of
ate on site initial-
ization
Operating mode
change-over (po-
sitioner; ON/OFF)
Activate/deactiv-
data
ate use of IO-Link
process data
Open request
Request valve po-
sition OPEN
Request valve po-
sition CLOSED
Open real
Real valve position
OPEN
Close real
Real valve position
CLOSED
Open
Analog value valve
position OPEN
Close
Analogue value
valve position
CLOSED
Stroke
Read out the ana-
log value for
stroke (difference
between OPEN
and CLOSED).
Max.
OPEN end position
Min.
CLOSED end posi-
Analog value po-
tentiometer
Analog value sup-
ply voltage
Temperature
Analog value tem-
perature sensor
Set value (W)
Analog value set
value signal
Open
Operating time
OPEN
Close
Operating time
CLOSE
Force
Force, dependent
on valve used
Force during ini-
tialization, de-
pendent on valve
25 / 53
12 Specific data IO-Link (pin 6)
Factory
settings
1 (0.1s)
sage
0
LEDs
0
0
0
900
(90.0%)
100
(10.0%)
tion
0
0
used
Setting options
1 ... 1000
(0.1s ... 100s)
0 → Standard
1 → Inversed
0 → Enabled
1 → Disabled
0 → Positioner
1 → On/Off
0 → Disabled
1 → Enabled
30 ... 970
(3.0 ... 97.0%)
30 ... 970
(3.0 ... 97.0%)
0 ... 4095
0 ... 4095
0 ... 4095
0 ... 4095
0 ... 4095
0 ... 4095
0 ... 4095
0 ... 4095
0 ... 4095
0 ... 4095
0 ... 4095
0 to 255
(0 to 25.5s)
0 to 255
(0 to 25.5s)
1 ... 6
1 ... 6
GEMÜ R563

Advertisement

Table of Contents
loading

Table of Contents