— Mask: 60/80/100 L/min
— Helmets/hoods/visors: 120/140/160 L/min
Briefly press either the full face mask pictogram or the protective hood pictogram to set the power-
assisted filtering system to the required air stream.
Check correct functioning of the alarm:
Dräger X-plore 7500 has a two-stage alarm. As soon as the air stream drops below the selected
flow rate and can no longer be compensated by the blower unit (e.g. NiMH battery charge too low/
filter loading too high), an acoustic warning signal sounds, the LEDs light up red and the blower
unit reduces the air stream to the next lower level. The acoustic warning signal sounds constantly
and the red LEDs flash when the lowest level is reached.
The red LED on the control panel shows how far the NiMH battery has become discharged.
Press and hold the left-hand arrow button for at least one second.
The fewer LEDs light up, the lower the charge in the NiMH battery.
The yellow LED on the control panel shows the extent to which the Dräger respiratory filter has be-
come contaminated (for combination filters, the contamination of the particle filter or the particle
filter components).
Press and hold the right-hand arrow button for at least one second.
The more LEDs light up, the greater the contamination of the Dräger respiratory filter.
When the arrow buttons are released, the LEDs light up green again and the air stream is indicated
again.
All Dräger filters must be replaced if the Dräger filters are exhausted.
The blower unit is functioning correctly if the LEDs light up green again after replacing the Dräger
respiratory filters.
The NiMH battery must be recharged if the alarm remains active.
The extent to which the gas filter or gas filter components have become contaminated is not indicated.
Pay attention to unusual smell and replace the filter if necessary!
Otherwise the health of the user could be damaged severely.
Connect the corrugated hose with the facepiece.

Donning the Facepiece

Half Mask/Full Face Mask
Use only the Dräger X-plore half masks and full face masks with standard thread connection accord-
ing to the order list.
Observe the Instructions for Use of the respective half masks and full face masks.
Only the corrugated hose Rd40 (part no. R 55 342) can be used in these combinations.
or
Dräger X-plore Hood/Welding Protection/Safety Helmet with Visor/Welder's
Visor
Use only the Dräger hoods/welding protections/safety helmets with visor/welder's visor according to
the order list.
Observe the Instructions for Use of the respective facepiece.
When using a TH2 facepiece, use the corrugated hose TH2 (part no. R 56 704).
When using the long hood TH3, use the corrugated hose TH3 (part no. R 55 571).
Dräger X-plore 7300/7500 is ready for use.