8
Important Information
1 Solvent
2 Aeration
3 Water separator
To fill without emissions, proceed as follows:
-
Remove the screw cap on the pump line.
-
Connect a hose between the barrel and pump suction side.
-
Connect gas displacement line between the barrel and water separator.
-
Open the ball valve.
-
Start program P51.
-
The tanks fill up, with one overflowing into the other.
-
Watch the level of the liquid in the tanks and stop program P51 when the tanks 1 and 2 are full.
-
fill tank 3 with P67
-
fill tank 2 once more with P51
-
Close the ball valve.
-
Remove the connecting lines to the barrel.
-
Screw the cap back on to the pump line.
-
Remove the gas displacement line.
If may be necessary to refill with solvent after the filter is filled each time you replace a filter.
8.1.3

Refilling Solvent

Follow the procedure given in Point 8.1.2 for routine refilling of solvent.
Attention: Even empty containers can still hold solvent residues.
48
Therefore, tightly seal the container (barrel) again and
store or dispose of in accordance with regulations!