5 Installation

5.1 Operating Environment

5.1.1

Regulations

You must observe applicable regulations concerning room ventilation and size,
odor and noise emissions, accident prevention, etc. The switch panel contains
contacts for the room ventilation control system (see Point 7.3.2).
Noise level:
approx. 60 dB (A)
(Average value taken from 6 measurement points at a distance of
2 m (6.5 feet) from the machine and
1.60 m (5.2 ft) above the floor
If there is an increase in the air-borne sound (for example, caused by resonance) because of the
spatial conditions at the place of installation (for example, the condition of and distances between
walls and ceiling), you must take sound insulation measures at the site.
5.1.2

Temperature

Do not expose the machine to direct sunlight. Ensure that there is an adequate air supply for the heat
exchange (heat buildup!).
The room temperature is not permitted to drop below 5 °C (41°F) because otherwise the water in the system
could freeze.
During continuous operation, the room temperature is not permitted to exceed 40 °C (104 °F) because of
increased solvent consumption and for safety reasons.
Heat dissipated to the surroundings: *
kJ/cycle
*
2-bath procedure, low level precleaning bath only for distillation
5.1.3

Structural Surroundings

Partitions, panels, suspended ceilings and other structures near the machine must be installed in
such a way that they do not interfere with the operation, that no heat buildup occurs and that they
can be easily removed for maintenance and repair work.
12
approx.
P12
P15
4000
4500
5
5.1
P18
5000
P12-P15-P18