8
Important Information
To fill without emissions, proceed as follows:
-
Remove the screw cap on the pump line.
-
Connect a hose between the barrel and pump suction side.
-
Connect gas displacement line between the barrel and water separator.
-
Open the ball valve.
-
Start program P51
-
The tanks fill up, with one overflowing into the other.
-
Watch the level of the liquid in the tanks and stop
program P51 when the tanks are full or when enough solvent has been filled in.
-
Close the ball valve.
-
Remove the connecting lines to the barrel.
-
Screw the cap back on to the pump line.
-
Remove the gas displacement line.
If may be necessary to refill with solvent after the filter is filled each time you replace a filter.

8.1.3 Refilling Solvent

Follow the procedure given in Point 8.1.2 for routine refilling of solvent.
Attention: Even empty containers can still hold solvent residues.
36
36
Therefore tightly seal the container (barrel) again and
store or dispose of in accordance with regulations!