Important Information
8.1.4

Filling Slimsorba Carbon Container (Optional Equipment)

-
Loosen the upper tube of the carbon container (disassemble hose connections, sensors and venting
line).
-
Loosen the quick release fastener on the cover and remove cover.
-
Remove fine filter sieve and clamping ring.
-
Fill in 13 kg-28.6 lb) of activated carbon (cylindrical pellets with approx. 4 mm (0.16 inch) diameter,
type Supersorbon K40). The heating coil must be covered.
-
Replace the fine filter sieve and clamping ring.
-
Replace the cover and close the quick release fastener.
-
Attach the upper tube of the carbon container again (assemble hose connections, sensors and
venting line.

8.2 Refrigeration Unit

Attention:
No cooling agent is allowed to escape into the atmosphere during
operation, servicing work and decommissioning of refrigeration units.
You must keep a record of the quantities of cooling agent used and
present this record to the authorities upon demand.
Only people who have the necessary special knowledge and technical
equipment are authorized to service and decommission refrigeration
units.