Section 13.0
The integrity of the System is only ensured if the user wears the recommended personal protective equipment (PPE). This should be
certified and marked in accordance with the relevant national standard. Using the wrong PPE or lanyards of incorrect length can result
in injury or death. Each system installed should be supplied with specifications of a full body harness, lanyards and shock absorbing
device. The following precautions, requirements and exclusions apply to the 3M™ DBI-SALA
• The System must be installed by an Certified 3M Fall Protection Installer or competent person trained by the manufacturer
or manufacturer's representative
• A recorded inspection must be conducted at least once a year by a Certified 3M Fall Protection Installer
• Do not attempt to test systems with dynamic or static loads. 3M Fall Protection Certified Installers carry the appropriate test
equipment for testing the Anchor and fixings
• The System must not be used for lifting
• Do not use the system for equipment tie back
• Never exceed the recommended number of users on the system (See label on product or system tag)
• Never attempt to repair, tamper with or change the System
• Do not use the system if it appears to be damaged or appears to have parts missing
• The equipment should not be used outside of its limitations, nor shall it be used for any other purpose than that intended.
• Each user should weigh no more than the maximum rated load for the energy absorbing lanyard. The lanyard shall be capable
of limiting the fall arrest load to less than 6 kN (1350 lbs)
• DO NOT attempt to clean the system with aggressive cleaning chemicals and abrasive products
• DO NOT use external systems in the event of a electrical storm
• Only personnel trained to work at height and in the correct operation of the systems should be permitted to use it
• In the unlikely event that a fall does occur the system should not be used until it has been inspected by a 3M Fall Protection
certified Installer
• Do not use the Anchor(s) if it is not clearly labelled
• If the cable is damaged, or if the cable is kinked, don't use the system.
Form No: 5903917 Rev: D