Maintenance Check List (Anchor) - 3M DBI-SALA RoofSafe Anchor User Instruction Manual

Table of Contents

Advertisement

3M™ DBI-SALA
Maintenance Check List
Section 9.0
CUSTOMER INFORMATION
INSPECTOR INFORMATION
Site Name:
Site Address:
ALL CHECKS MUST BE CARRIED OUT IN ACCORDANCE WITH CURRENT TECHNICAL DOCUMENTATION AND INSTRUCTIONS.
CHECKLIST
ALL SYSTEMS
Visual inspection. Check system for signs of a fall event
Check system ID Tag is present and legilble
Check all components for signs of damage, rusting or severe corrosion
Check all components are isolated from disimilar metals
Check integrity of structure
Check split pins present and in good condition
Check that Unieyes/End Anchorages are correctly orientated and in good condition
Check fasteners are correctly tightened. Use Torque Wrench as required
Proof load test concrete fixings to 6kN
Clean system as necessary
Check Attachment Devices operate correctly
CABLE SYSTEMS
Uni 16™ Only. Check finishing kit elements are present and intact
Check cable condition for fretting, corrosion, signs of contamination and damage
Cable tension OK
Check Uni 8™ Tensioners for correct thread engagement and ensure lock nuts are tight
Check inline energy absorbing elements are intact
Check intermediate brackets are not deployed and nylon shear pins are intact
RoofSafe™ Anchors
Check energy absorbing elements are not deployed
Ensure all waterproofing elements are present and intact
Check standing seam clamps with a torque wrench
RAIL SYSTEMS
Check system, carriage and end stops are securely fixed
Check system for cracks in rail
Check rail for signs of deformation
Roofsafe rivets hand checked for secure fixing - tug anchorage at each section
Check all joints are securely fixed
RoofSafe™ - Check spreader plate correctly riveted in X pattern
RoofSafe™ - Check grub screws in corners are secure. Torque to 5Nm
NOTES AND IMPORTANT OBSERVATIONS
System in good condition and cleared for use
Inspector's
Signature
Form No: 5903917 Rev: D
Form No: 5903917 Rev: D
RoofSafe Anchor and Cable System
®
Maintenance Check Sheet
INSPECTION INFORMATION
3M Fall Protection ID No:
Inspection Date:
Name:
System Type:
Bituminous RA
Address:
RoofSafe™
Telephone:
System ID/Reference No:
NOTES
System not acceptable, further action required
Print
Name
Stand Seam RA
Top Fix RA
Single Ply RA
Secret Fix RA
Uni 8™ 7x7
Uni 16™
Uni 8™ Overhead
UniRail™
Cabloc™
Cabloc™ Pro
Other
Next Inspection
Due Date