4004_RevDB.fm Page 8 Wednesday, November 23, 2011 3:06 PM
Quick Installation Guide
00825-0100-4004, Rev DB
Rosemount 8800D
December 2011
CAUTION
Do not rotate the housing while the sensor cable is attached to the base of the housing. This
will stress the cable and may damage the sensor.
6. Place the electronics housing into the top of the support tube.
7. Use a 5/32" hex wrench to turn the three housing rotation screws counter-clockwise
(outward) to engage the support tube.
S
3: S
J
TEP
ET
UMPERS
Adjust jumpers to desired settings.
HART
If alarm and security jumpers are not installed, the flowmeter will operate normally with the
default alarm condition alarm high and the security off.
Figure 9. HART Jumpers and LCD
LO
HI
ALARM
SECURITY
ON
OFF
F
fieldbus
OUNDATION
If security and simulate enable jumpers are not installed, the flowmeter will operate normally
with the default security off and simulate enable off.
Figure 10. F
fieldbus Jumpers and LCD
OUNDATION
ON
OFF
SIMULATE ENABLE
SECURITY
ON
OFF
8