Group C: Power Parameters - Bosch Rexroth VFC 3210 Series Quick Start Manual

Frequency converter
Hide thumbs Also See for Rexroth VFC 3210 Series:
Table of Contents

Advertisement

24/51
Start-up

3.3.3 Group C: Power Parameters

C0: Power control parameters
Code
Name
C0.05 Carrier frequency
Carrier frequency
C0.06
automatic adjustment
C0.07 PWM mode
DPWM switchover frequency
C0.08
upper limit
C0.10 Automatic voltage stabilization
Automatic voltage stabilization
C0.11
reference voltage
Overvoltage suppression ad-
C0.23
justment gain
Stall overvoltage hysteresis
C0.24
voltage
C0.25 Overvoltage prevention mode 0, 1, 4
Stall overvoltage
C0.26
prevention level
Stall overcurrent
C0.27
prevention level
C0.28 Phase loss protection mode
Converter overload
C0.29
pre-warning level
Converter overload
C0.30
pre-warning delay
Bosch Rexroth AG R912007861_Edition 02
Setting range
2...12 kHz
0: Inactive
1: Active
2: Fixed carrier frequency
0: SVPWM
1: SVPWM with overmodu-
lation
2: DPWM
3: DPWM with overmodu-
lation
8.00...400.00 Hz
0: Always active
1: Always inactive
2: Inactive only during de-
celeration
1P 200 VAC: 180...264 V
3P 380 VAC: 323...528 V
0.00...10.00
0...100 V
1P 200 VAC: 300...390 V
3P 380 VAC: 600...785 V
20.0 %...[C2.42]
0...3
20.0...200.0 %
0.0...20.0 s
Rexroth Frequency Converter VFC 3210
Default
4
1
DOM
12.00
0
220
380
1.00
1P: 30
3P: 50
1
385
770
150.0
3
110.0
2.0
Min.
Attri.
1
Run
Stop
Run
0.01
Run
1
Stop
1
Stop
0.01
Run
1
Stop
Stop
1
Stop
0.1
Stop
Run
0.1
Stop
0.1
Stop

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents