Rexroth Frequency Converter VFC 3210
1 Mechanical Installation
1.1 Visual Check
After unpacking the frequency converter, perform a thorough visual check.
Check the following:
The right device has been supplied
●
The device has no damage
●
No transport damage such as scratches, cracks or dents
●
If you find any deviation from one of the above points, please contact your
Bosch Rexroth sales partner.
1.2 Ambient Conditions
If it is to function perfectly, the frequency converter must be installed in an envi-
ronment matching the data provided below.
Rated ambient temperature
Derating / ambient temperature
Rated altitude
Derating / altitude
Relative humidity
Degrees of protection
Degrees of pollution
Tab. 1-1: Ambient conditions
-10...40 °C
1.5 % / 1 °C (40...50 °C)
≤ 1,000 m
1 % / 100 m (1,000...2,000 m)
≤ 90 % (No condensation)
IP 20 (Control cabinet mounting)
2 (EN 50178)
R912007861_Edition 02 Bosch Rexroth AG
1/51