Checking Start-Up Parameters - Bosch Rexroth VFC 3210 Series Quick Start Manual

Frequency converter
Hide thumbs Also See for Rexroth VFC 3210 Series:
Table of Contents

Advertisement

Rexroth Frequency Converter VFC 3210

3.2.3 Checking Start-up Parameters

Set [b0.00] = '3: Start-up parameters', and then check all start-up parameters.
For terminology and abbreviation in the above table, see
nology and Abbreviation in Parameter List" on page
Code
Name
C0.05 Carrier frequency
C1.05 Motor rated power
C1.06 Motor rated voltage
C1.07 Motor rated current
C1.08 Motor rated frequency
C1.09 Motor rated speed
C2.00 V/f curve mode
E0.00 First frequency setting source
E0.01 First run command source
E0.07 Digital setting frequency
E0.08 Maximum output frequency
E0.09 Output frequency high limit
E0.10 Output frequency low limit
E0.17 Direction control
Acceleration / Deceleration
E0.25
curve mode
E0.26 Acceleration time
E0.27 Deceleration time
E0.35 Start mode
E0.50 Stop mode
Tab. 3-4: Start-up parameters
23.
Setting range
DOM
0.1...1,000.0 kW
0...480 V
0.01...655.00 A
5.00...400.00 Hz
1...30,000 rpm
0: Linear
1: Square
2: User-defined
0...21
0...2
0.00...[E0.09] Hz
50.00...400.00 Hz
[E0.10]...[E0.08] Hz
0.00...[E0.09] Hz
0: Forward/Reverse
1: Forward only
2: Reverse only
3: Swap default direction
0: Linear mode
1: S-curve
0.1...6,000.0 s
0.1...6,000.0 s
0: Start directly
1: DC-braking before start
2: Start with speed tracing
3: Automatic start / stop ac-
cording to setting frequency
0: Decelerating stop
1: Freewheeling stop 1
2: Freewheeling stop 2
R912007861_Edition 02 Bosch Rexroth AG
Start-up
chapter 3.3.1 "Termi-
Default
Min.
DOM
1
DOM
0.1
DOM
1
DOM
0.01
50.00
0.01
DOM
1
0
0
0
50.00
0.01
50.00
0.01
50.00
0.01
0.00
0.01
0
0
DOM
0.1
DOM
0.1
0
0
21/51
Attri.
Run
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Stop
Run
Stop
Run
Run
Stop
Stop
Run
Run
Stop
Stop