Rexroth Frequency Converter VFC 3210
E3: Multi-speed and simple PLC parameters
Code
Name
E3.00 Simple PLC running mode
E3.01 Simple PLC time multiplier 1...60
E3.02 Simple PLC cycle number 1...1,000
E3.10 Acceleration time 2
E3.11 Deceleration time 2
E3.12 Acceleration time 3
E3.13 Deceleration time 3
E3.14 Acceleration time 4
E3.15 Deceleration time 4
E3.16 Acceleration time 5
E3.17 Deceleration time 5
E3.18 Acceleration time 6
E3.19 Deceleration time 6
E3.20 Acceleration time 7
E3.21 Deceleration time 7
E3.22 Acceleration time 8
E3.23 Deceleration time 8
E3.40 Multi-speed frequency 1
E3.41 Multi-speed frequency 2
E3.42 Multi-speed frequency 3
E3.43 Multi-speed frequency 4
E3.44 Multi-speed frequency 5
E3.45 Multi-speed frequency 6
E3.46 Multi-speed frequency 7
E3.59 Stage 0 frequency source
Setting range
0: Inactive
1: Stop after selected cycle
2: Continuously cycling
3: Run last stage after selected cycle
0.1...6,000.0 s
0.1...6,000.0 s
0.1...6,000.0 s
0.1...6,000.0 s
0.1...6,000.0 s
0.1...6,000.0 s
0.1...6,000.0 s
0.1...6,000.0 s
0.1...6,000.0 s
0.1...6,000.0 s
0.1...6,000.0 s
0.1...6,000.0 s
0.1...6,000.0 s
0.1...6,000.0 s
0.00...[E0.09] Hz
0.00...[E0.09] Hz
0.00...[E0.09] Hz
0.00...[E0.09] Hz
0.00...[E0.09] Hz
0.00...[E0.09] Hz
0.00...[E0.09] Hz
0: Digital setting frequency
1: AI analog input
5: Communication
6: Panel potentiometer
7: Digital input up/down command
R912007861_Edition 02 Bosch Rexroth AG
35/51
Start-up
Default
Min.
Attri.
0
–
Stop
1
1
Stop
1
1
Stop
10.0
0.1
Run
10.0
0.1
Run
10.0
0.1
Run
10.0
0.1
Run
10.0
0.1
Run
10.0
0.1
Run
10.0
0.1
Run
10.0
0.1
Run
10.0
0.1
Run
10.0
0.1
Run
10.0
0.1
Run
10.0
0.1
Run
10.0
0.1
Run
10.0
0.1
Run
0.00
0.01
Run
0.00
0.01
Run
0.00
0.01
Run
0.00
0.01
Run
0.00
0.01
Run
0.00
0.01
Run
0.00
0.01
Run
0
–