Danfoss VLT AutomationDrive FC 301 Instruction Manual page 64

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Specifications
Type Designation
High/Normal Overload
Typical Shaft output at 550 V hp (kW)
Typical Shaft output at 690 V hp [kW]
Enclosure IP20
Enclosure IP21, IP55
Output current
Continuous (3x525–550 V) [A]
Intermittent (60 s overload)
(3x525–550 V) [A]
Continuous (3x551–690 V) [A]
Intermittent (60 s overload)
(3x551–690 V) [A]
continuous KVA (at 550 V AC) [KVA]
continuous KVA (at 690 V AC) [KVA]
Max. input current
Continuous (at 550 V) [A]
Intermittent (60 s overload) (at 550 V) [A]
8
8
Continuous (at 690 V) [A]
Intermittent (60 s overload) (at 690 V) [A]
Additional specifications
Max. cable-cross section for line power
and motor [mm
Max. cable cross-section for load share and
2
brake [mm
] ([AWG])
Max cable cross-section
disconnect [mm
Estimated power loss
at rated max. load hp [W]
2)
Efficiency
Table 8.12 B4, C2, C3 Enclosure, Line Power Supply 3x525–690 V AC IP20/IP21/IP55 - Chassis/NEMA1/NEMA 12 (FC 302 only),
P30K-P75K
For fuse ratings, see chapter 8.7 Fuses and Circuit Breakers.
1)
High overload=150% or 160% torque during 60 s. Normal overload=110% torque during 60 s.
2)
Measured using 16.5 ft. [5 m] shielded motor cables at rated load and rated frequency.
3)
The typical power loss is at nominal load conditions and expected to be within
cable conditions).
Values are based on a typical motor efficiency (eff2/eff3 border line). Motors with lower efficiency will also add to the power loss in the
adjustable frequency drive and vice-versa.
If the switching frequency is increased compared to the default setting, the power losses may rise significantly.
LCP and typical control card power consumption values are included. Further options and customer load may add up to 30 W to the
losses. (Though typical only 4 W extra for a fully loaded control card, or options for slot A or slot B, each).
Although measurements are made with state of the art equipment, some measurement inaccuracy must be allowed for (
4)
The three values for the max. cable cross-section are for single core, flexible wire and flexible wire with sleeve, respectively.
62
1)
HO
30 [22]
40 [30]
36.0
54.0
34.0
51.0
34.3
40.6
36.0
54.0
36.0
54.0
2
] ([AWG])
4)
for line power
2
] ([AWG])
0.811
3)
[600]
Danfoss A/S © Rev. 2014-02-10 All rights reserved.
Instruction Manual
P30K
P37K
NO
HO
NO
40 [30] 40 [30]
50 [37]
50 [37] 50 [37]
60 [45]
B4
C3
C2
C2
43.0
43.0
54.0
47.3
64.5
59.4
41.0
41.0
52.0
45.1
61.5
57.2
41.0
41.0
51.4
49.0
49.0
62.1
49.0
49.0
59.0
53.9
72.0
64.9
48.0
48.0
58.0
52.8
72.0
63.8
95, 70, 70
(3/0, 2/0, 2/0)
1.00
1.00
1.216
[740]
[740]
[900]
0.98
0.98
P45K
P55K
HO
NO
HO
NO
50 [37]
60 [45]
60 [45]
75 [55]
60 [45]
75 [55]
75 [55] 100 [75] 100 [75] 125 [90]
C3
D3h
C2
C2
54.0
65.0
65.0
87.0
81.0
71.5
97.5
95.7
52.0
62.0
62.0
83.0
78.0
68.2
93.0
91.3
51.4
61.9
61.9
82.9
62.1
74.1
74.1
99.2
59.0
71.0
71.0
87.0
87.0
78.1
105.0
95.7
58.0
70.0
70.0
86.0
87.0
77.0
105
94.6
150 (300 MCM)
95 (3/0)
185, 150, 120
(350 MCM, 300
MCM, 4/0)
1.216
1.486
1.486
2.027
[900]
[1100]
[1100]
[1500]
0.98
0.98
± 15% (tolerance relates to variety in voltage and
P75K
HO
NO
68 [50] 100 [75]
D3h
C2
87.0
105
130.5
115.5
83.0
100
124.5
110
82.9
100
99.2
119.5
87.0
99.0
129
108.9
-
-
-
-
-
2.027
2.432
[1500]
[1800]
0.98
± 5%).
MG33AN22