In a multi-port input configuration, the projector requires all signals to have a stable sync. The
projector automatically selects the top-left signal as the master signal to use as reference. If the
master is unstable, all of the other signals look unstable. Possible symptoms of the issue include:
Non-master signals constantly locking and unlocking
Dropped frames in the affected sections of the display
Tearing in the affected sections of the display
Possible root causes include the master signal or non-master signals not having stable syncs.
For more details, refer to the following:
Signal Group (SST+SIGN?) section in the
101259-XX)
and
Troubleshooting > Incoming signal(s) problems section in the following manuals:
D4K2560 User Manual (P/N: 020-101076-XX)
Mirage 4K25 User Manual (P/N: 020-101361-XX)
D4K3560 User Manual (P/N: 020-101075-XX)
Mirage 4K35 User Manual (P/N: 020-101377-XX)
Solution
Change Slot 1 Input 1 cable (master) with the Slot 3 Input 1 cable. If the master signal is the issue,
only Slot 3 Input 1 should show the lock/unlock symptom. If the video source is the issue, the
symptoms should remain the same.

Screen has reversed colors

The screen has reversed colors (such as the blue and green are swapped) and the Formatter
Mismatch alarm appears in the Status tab of the TPC. For example:
Formatter - Green HW Version
Formatter - Blue HW Version
Details
The formatters are not connected correctly to the high speed image processor board (HIP)—the
above example illustrates the green and blue formatters.
For more information, refer to the following:
D4K Status System Technical Reference (P/N: 020-101259-XX)
Mirage 4K Status System Technical Reference (P/N: 020-101450-XX)
D4K2560 Interconnect Drawing (P/N: 020-101088-XX)
D4K and Mirage 4K Troubleshooting Technical Reference
020-101452-03 Rev. 1 (10-2014)
Mirage 4K Status System Technical Reference (P/N:
Mismatch Blue
Mismatch Green
D4K and Mirage 4K Troubleshooting
D4K Status System Technical Reference (P/N: 020-
020-101450-XX).