D11. Temperature Zone

A temperature zone uses a wireless temperature detector to
detect both indoor and outdoor temperatures and is
permanently active. The detector monitors room temperature
using an internal sensor. For outdoor or refrigerator
installations, a waterproof temperature probe (optional) is
used. There are a total of four fixed temperature points and
the user can enable one or more temperature point.
Upon detection of change in temperature a digital
message is transmitted and the event is reported.

APPENDIX E. PowerMax Pro Compatible Devices

E1
Compatible Detectors
Each detector compatible with the PowerMax Pro system
is packed with its own installation instructions. Read them
carefully and install as indicated.
A. PIR Motion Detectors
The wireless passive infrared (PIR) motion detectors used
in the system are of the PowerCode type. The PowerMax
Pro is capable of "learning" each detector's identification
code and linking it to a specific zone (see par. 4.3 in this
Guide). Some units are shown below:
®
NEXT
MCPIR-3000
K9-85 MCW
or K-940 MCW
Note: K-940 MCW, Discovery K9-80/MCW and NEXT
K9-85 MCW are pet immune units.
In addition to its unique 24-bit identification code, each
detector
transmits
a
information:
• The detector is in alarm (or not).
• The detector is being tampered with (or not).
• The battery voltage is low (or normal).
• "This is a supervisory message".
If any of these detectors detects motion, it sends out a
message to the alarm control panel. If the system is in the
armed state, an alarm will be triggered.
Wireless
PowerCode
Detector CLIP MCW. A curtain-pattern
PIR detector for indoor use and designed
for easy installation. An advanced motion
analysis method allows the CLIP MCW to
distinguish between the true motion of the
human body and any other disturbances
that cause false alarms. After detection,
the detector disarms itself to save battery
power. It rearms (reverts to the ready
state) if there is no subsequent detection
throughout the following 2-minute period.
Dual
technology
NEXT PLUS Detectors. The NEXT
PIR is a microprocessor-controlled PIR
detector, designed for easy installation,
free of vertical adjustment. It features a
cylindrical lens with uniform detection
sensitivity of up to a distance of 15 meters
(49 ft) from the detector.
34
DISCOVERY
K9-80/MCW
message,
containing
Infrared
CLIP MCW
anti-masking
NEXT PLUS

D12. 24-Hour Zones

24 hour zones are mainly used for PANIC buttons,
perimeter detectors and anti-tamper protection. They
therefore trigger an alarm in both armed and disarmed
states.
• 24 Hour Zone - Silent. - Upon detection, this zone
initiates a silent alarm, meaning that the sirens do not
function. Instead the PowerMax Pro dials telephone
numbers and reports the event to central stations and/or
to private telephones, as programmed.
• 24 Hour Zone - Audible. - Upon detection, this zone
initiates a siren alarm. The PowerMax Pro also dials
telephone numbers and reports the event to central
stations and/or to private telephones, as programmed.
Wireless PowerCode PIR Detector
TOWER 40. A microprocessor-controlled
wireless digital PIR detector, designed for
easy installation, free of vertical adjustment.
It features parabolic and cylindrical mirrors
with uniform detection sensitivity throughout
its operating range, up to 18 meters (59 ft),
with creep zone protection. An advanced
True
Motion
(patented) allows the TOWER 40 to
distinguish between the true motion of an
intruder and any other disturbances which
may cause false alarms.
B. Magnetic Contact Transmitter
MCT-302 is a PowerCode magnetic-
contact transmitter used to detect the
opening of a door or a window. The alarm
contacts are closed as long as the door or
window remains closed.
®
The unit has an extra alarm input that acts as if it were a
separate wireless transmitter. It sends (or does not send) a
"restored to normal" message to the alarm system,
status
depending on the setting of an on-board "DIP" switch. The
"restore" message informs you, through the control panel's
display, whether the door or window is open or closed.
C MCT-100 Wireless Adapter for
Wired
Detectors.
PowerCode device used mainly as a
wireless adapter for 2 regular magnetic
switches installed on 2 windows in the
same room. It has two inputs, behaving as
separate wireless transmitters with different
PowerCode IDs. Each input sends (or does
not send) a "restored" message to the
alarm system, depending on the setting of
an on-board "DIP" switch.
D.
Wireless
MCT-425.
detector equipped with a PowerCode-
type transmitter. If enrolled to a fire zone,
it initiates a fire alarm upon detection of
smoke.
E.
Wireless
Detector MCT-441. A natural gas
detector designed to send an alarm when
Methane gas is detected. The detector can
be used in a house, apartment, caravan,
mobile home or yacht. The detector can
send the following messages to the alarm
control panel: Gas alarm, gas sensor failure,
AC power failure and low battery voltage.
Recognition™
algorithm
MCT-100
is
Smoke
Detector
A
photoelectric
smoke
PowerCode
Gas
TOWER 40
MCT-302
a
MCT-100
MCT-425
MCT-441
DE5468IP

Advertisement

Table of Contents
loading

Table of Contents