Visonic POWERMAX PRO Installer's Manual page 17

Fully supervised wireless alarm control system
Hide thumbs Also See for POWERMAX PRO:
Table of Contents

Advertisement

READY 00:00
NORMAL MODE
USER SETTINGS
INSTALLER MODE
ENTER CODE
[installer code]
1. NEW INSTL CODE
2. ENROLLING
3. DEFINE ZONES
4. DEFINE PANEL
5. DEFINE COMM
6. DEFINE GSM
7. DEFINE PWRLNK
8. DEFINE OUTPUTS
9. DEFINE VOICE
10. DIAGNOSTICS
11. USER SETTINGS
12. FACTORY DEFLT
13. SERIAL NUMBER
14. START UL/DL
<OK> TO EXIT
Note: The currently saved
options are displayed with
dark box at the right side of
the display. To review the
options, repeatedly click
or
until the
desired option is displayed,
then click OK (a dark box
will be displayed at the right
side).
Not applicable
in the USA
Not applicable
in the USA
DE5468IP
01: ENTRY DELAY 1
entry dly1 00 s
entry dly1 15 s
entry dly1 30 s
entry dly1 45 s
entry dly1 60 s
entry dly1 3 m
entry dly1 4 m
05: ABORT TIME
abort time 00 s
abort time 15 s
abort time 30 s
abort time 45 s
abort time 60 s
abort time 2 m
abort time 3 m
abort time 4 m
09: EXIT MODE
restart exit
off by door
normal
13: SWINGER STOP
shut after 1
shut after 2
shut after 3
in
USA
no shutdown
Note: Swinger Stop is defined
for entire alarm system.
17: AUX BUTTON A
status
instant
skip exit delay
PGM / X-10
21: NOT ACTIVE
no act time 3 h
no act time 6 h
no act time 12 h
no act time 24 h
no act time 48 h
no act time 72 h
no act disable
25: RESET OPTION
user reset
enginner reset
29: DISARM OPTION
any time
on entry wireless
entry + awake kp
on entry all
in
UK
33: CONFIRM TIME
disable
30 minutes
45 minutes
60 minutes
90 minutes
Figure 4.4 - DEFINE PANEL Flow Chart
02: ENTRY DELAY 2
entry dly2 00 s
entry dly2 15 s
entry dly2 30 s
entry dly2 45 s
entry dly2 60 s
entry dly2 3 m
entry dly2 4 m
06: ALARM CANCEL
cancel time 1 m
cancel time 5 m
cancel time 15 m
cancel time 60 m
cancel time 4 h
cancel inactive
in
USA
10: PIEZO BEEPS
enable beeps
off when home
disable beeps
in
USA
14: CROSS ZONING
cross zone ON
cross zone OFF
18: AUX B 2-W-KF
status
instant
skip exit delay
PGM / X-10
22: BACK LIGHT
always on
off after 10 s
26: TAMPER OPTION
zone tamper on
zone tamper off
30: BELL/REP. OPT
EN standard
other
34: AC FAIL REP
5 minutes
30 minutes
60 minutes
180 minutes
03: EXIT DELAY
exit delay 30 s
exit delay 60 s
exit delay 90 s
exit delay 120 s
exit delay 3 m
exit delay 4 m
07: QUICK ARM
quick arm ON
quick arm OFF
11: TROUBLE BEEPS
disable beeps
enable beeps
in
off at night
USA
15: SUPERVISION
superv time 1 h
superv time 2 h
superv time 4 h
superv time 8 h
superv time 12 h
disable
19: JAM DETECT
UL (20/20)
EN (30/60)
class 6 (30/60)
disabled
23: DURESS
duress code 2580
(Change the code or
enter 0000 to disable
duress function)
Note: Duress code is not
applicable to the UK.
27: SIREN ON LINE
enable on fail
disable on fail
31: LOW-BAT ACK
keyfob L-B on
keyfob L-B off
36: USER PERMIT
disable
enable
in
UK
04: BELL TIME
bell time 1 m
bell time 3 m
bell time 4 m
bell time 8 m
bell time 10 m
bell time 15 m
bell time 20 m
08: BYPASS
manual bypass
no bypass
force arm
Note: Force arm is not
applicable to the UK.
12: PANIC ALARM
silent panic
audible panic
disable panic
16: NOT READY
normal
in supervision
20:LATCHKEY
latchkey on
latchkey off
24: PIEZO SIREN
piezo siren on
piezo siren off
28:MEMORY PROMPT
enable
disable
32: SCREEN SAVER
scrn saver OFF
refresh by code
refresh by key
17