Visonic POWERMAX PRO Installer's Manual page 12

Fully supervised wireless alarm control system
Hide thumbs Also See for POWERMAX PRO:
Table of Contents

Advertisement

ENROLLING TYPE
normal enroll
by tamper
(Display when partition
is enabled)
P1 RDY 00:00
NORMAL MODE
USER SETTINGS
INSTALLER MODE
ENTER CODE
[installer code]
1. NEW INSTL CODE
2. ENROLLING
3. DEFINE ZONES
4. DEFINE PANEL
5. DEFINE COMM
6. DEFINE GSM
7. DEFINE PWRLNK
8. DEFINE OUTPUTS
9. RECORD SPEECH
10. DIAGNOSTICS
11. USER SETTINGS
12. FACTORY DEFLT
13. SERIAL NUMBER
14. START UL/DL
15. PARTITIONING
16. SHOW LOG
<OK> TO EXIT
Figure 4.2 - Enrolling / Deleting Wireless Devices / Keyfobs / Wireless Commanders / Wireless Sirens
*
Keyfob & proximity tags enrolling can be performed by
the installer or by the user (via USER SETTINGS
menu).
** Black box in the display means that a device is enrolled
(the system has learned its ID). No black box indicates
that the device is not enrolled.
12
ENROLL SENSORS
higher sensitivity
lower sensitivity
[wired Zone No.
29/30] (e.g. 29)
ZONE No: 29
ZONE No: 05
<OK> TO ENROLL
TRANSMIT NOW
[Initiate transmission)
ZONE No: 29
ZONE No: 05
for next
enrolling action
enrolling action
Enrolling wired sensor
Enrolling a WL Sensor
ENROL WL 1WAY KP
1way kp No :
[WL 1-way keypad
No. 1 to 8] (e.g. 5)
1way kp No : 5
TRANSMIT NOW
press
*
key until
red LED
lights
Partition
Partition 1
[select partition 1 - 4]
Commander MCM-140+
1way kp No: 5
for next
enrolling action
Enrolling a wireless
Commander MCM-140+
ENROL WL SIREN
SIREN No :
[WL siren No.
1 or 2] (e.g. 2)
siren No : 2
TRANSMIT NOW
Momentarily press the
wireless siren self-test
button until a squawk is
heard (1 sec. approx.)
siren No: 2
for next
enrolling action
Enrolling a
wireless siren
SET SENSITIV.
(****)
Select by
or
ZONE No: - -
[WL Zone No.
[wired/WL Zone No.
01-28] (e.g. 05)
01-30] (e.g. 05)
ZONE No: 05
<OFF> TO DELETE
(**)
(***)
ZONE No: 05
for next
Deleting wired/
WL sensor
(**)
1way kp No : 5
<OFF> TO DELETE
1way kp No: 5
Deleting a wireless
(**)
siren No : 2
Open WL
siren cover
and remove
its battery
<OFF> TO DELETE
siren No: 2
Deleting a
wireless siren
***
Initiate either normal transmission or the device
tamper function (see ENROLLING TYPE, Par. 4.2.2).
**** Select "higher" sensitivity for far wireless device,
"lower" for near devices.
***** MKP-150/151 is not compatible for use when partition
is enabled.
(*)
ENROLL KEYFOB
Keyfob No: -
[Keyfob No.]
Keyfob No: 5
TRANSMIT NOW
(press
any
key)
(**)
Partition
(**)
Partition 1
[select partition 1 - 4]
KEYFOB No: 05
for next
enrolling action
Enrolling a Keyfob
ENROL WL 2WAY KP
(*****)
2way kp No:
[MKP-150/151
No. 1 or 2] (e.g. 2)
2way kp No : 2
TRANSMIT NOW
Press MKP-
150/151
back tamper
switch once
(see MKP-
150/151
AWAY
inst. instructions)
2way kp No: 2
for next
enrolling action
Enrolling a wireless
keypad MKP-150/151
(*)
ENROLL PROX TAG
Tag No: -
(Prox tag No.)
(e.g. 5)
Tag No: 5
PRESENT TAG
Present
tag
(**)
Tag No: 05
for next
enrolling action
Enrolling a Prox tag
(**)
(e.g. 5)
Keyfob No: 5
<OFF> TO DELETE
KEYFOB No: 05
Deleting a Keyfob
(**)
2way kp No : 2
<OFF> TO DELETE
2way kp No: 2
Deleting a wireless
keypad MKP-150/151
(**)
Tag No: 5
<OFF> TO DELETE
Tag No: 05
Deleting a prox tag
DE5468IP

Advertisement

Table of Contents
loading

Table of Contents