Fm Critical And Maximum Squelch Sensitivity Measurement - HP 8920A Application Handbook

Rf communications test set
Hide thumbs Also See for 8920A:
Table of Contents

Advertisement

FM Receivers

FM Critical and Maximum Squelch Sensitivity Measurement

Description
This procedure is used to measure an FM Receiver's critical squelch
and maximum squelch sensitivity. For critical squelch, the receiver is
just squelched with minimum modulated input at the Receiver's
antenna, then the input is increased until the squelch is opened.
Maximum squelch is the amount of modulated signal required to open
the squelch when the control is set to maximum. Minimum and
maximum squelch hysteresis is also measured and calculated. The FM
reference is EIA/TIA-204-D.
RX TEST
RF IN/OUT
DUPLEX OUT
POWER
OFF
ON
MAX POWER 6 0 W
!
CONTINUOUS
50Ω COXIAL
CABLE
94
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
3
Knob
SCREEN CONTROL
MSSG
HELP
CONFIG
RX
TX
DUPLEX
USER
DATA FUNCTIONS
k1'
REF SET
METER
INCR
INCR
k1
: 10
SET
k2'
LO LIMIT
k2
k3'
CURSOR CONTROL
k3
ASSIGN
k4
RELEASE
PUSH TO SELECT
k5
SHIFT
CANCEL
MIC/ACC
VOLUME
ANT IN
!
MAX POWER 200 mW
ANTENNA (RF INPUT)
Data Entry
2
Keys
INSTRUMENT STATE
HOLD
PRINT
ADRS
SAVE
MEAS
PREV
TESTS
LOCAL
RECALL
PRESET
RESET
DATA
AVG
INCR X10
7
8
9
ENTER
HI LIMIT
dB
GHz
4
5
6
dBm
%
MHz
1
2
3
V
s
+ _
kHz
0
mV
YES
NO
ms
ppm
%
Hz
ON/OFF
µV
W
dBµV
MEM ORY
CARD
SQUELCH
AUDIO OUT
AUDIO IN
HI
LO
MAX
M AX
!
!
12 v Pk
4 2 v Pk
1
RECEIVER UNDER TEST

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8920b

Table of Contents