AM Measurement
Frequency Range: 10 MHz to 1 GHz (usable to 400 kHz)
Depth: 0 to 95%
Accuracy: ±5% of reading ±1.5% AM (50 Hz to 10 kHz rates, modulation
≤80%)
THD+Noise: <2% rms for modulation ≤80% AM (1 kHz rate in a 0.3 to 3
kHz BW)
Input Level for Specified Accuracy (levels in PEP):
Residual AM: <0.2% in a 0.3 to 3 kHz BW
Resolution: 0.1%
SSB Measurement
Frequency Range: 400 kHz to 1 GHz
Bandwidth (3 dB): 20 Hz to 70 kHz
Distortion and Noise: <3% at 1 kHz rate in a 0.3 to 3 kHz BW
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Standard:
−18 to +50 dBm at RF IN/OUT (0.016 mW to 100 W)
−50 to +14 dBm at ANT IN
Option 007:
−32 to 36 dBm at RF IN/OUT (0.63 µW to 4.0 W)
RF Analyzer Specifications