FM Receivers
On the Test Set using the knob and data entry keys:
13 Slowly increase the Amplitude until squelch just remains open.
Critical Squelch is displayed as Amplitude as shown.
Squelch
Sensitivity
14 Decrease Amplitude until the Receiver's squelch just closes.
Calculate the measurement:
15 Critical Squelch Hysteresis is the difference between the two readings.
On the Radio set the Receiver's Controls as follows:
16 Set the Receiver's squelch control to maximum.
On the Test Set using the knob and data entry keys:
17 Increase Amplitude until the Receiver's squelch just opens.
18 Record the maximum squelch sensitivity is displayed as Amplitude as
shown.
19 Decrease Amplitude until the Receiver's squelch just closes.
Calculate the reading:
20 Maximum Squelch Hysteresis is the difference between the two readings.
96
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Record this level.
SINAD
0
2.23
Avg
RF Gen Freq
AFGen1 Freq
145.280000
MHz
AFGen1 To
Amplitude
FM
0.0890
uV
Atten Hold
On/Off
Output Port
RF Out/Dupl
Record this level.
Record this level.
Record this level.
RX TEST
AC Level
dB
dB
-20.34
24
Ref
To Screen
AFGen2 Freq
Filter 1
1.0000
1.0000
RF GEN
50Hz HPF
kHz
kHz
RF ANL
AF ANL
AFGen2 To
Filter 2
SCOPE
FM
15kHz HPF
3.00
Off
SPEC ANL
kHz
ENCODER
DECODER
Ext Load R
RADIO INT
8.00
More