Installation Drawings/Dimension Drawings; Installation Situation For Motors With A Cooling Jacket; Information On The Installation Drawings - Siemens SIMOTICS T-1FW6 Series Configuration Manual

High speed built-in torque motors
Hide thumbs Also See for SIMOTICS T-1FW6 Series:
Table of Contents

Advertisement

Installation drawings/Dimension drawings

9.1

Installation situation for motors with a cooling jacket

Design information for installation hole and O ring
● Provide insertion inclines: Minimum length Z at 15°: 3 mm, at 20°: 2 mm, edges rounded
and polished
Debur and round inside holes (cooling water connections)
● Surface quality of the opposite sealing surfaces: R
● Note the installation hole fit (H8). If the play is too great, the O-ring does not provide
sufficient sealing or the permissible gap is too large.
Figure 9-1
9.2

Information on the installation drawings

Note
Observe the permissible mounting side
For design reasons, some motors must only be mounted on the DE flange. In this respect,
note the table "Permissible mounting side" in Chapter "Specification of the installation side
(Page 115)".
1FW6 High Speed built-in torque motors
Configuration Manual, 01/2020, 6SN1197-0AE03-0BP3
Design information for installation hole and O ring
≤ 16 µm, R
≤ 10 µm, R
max
z
9
≤ 1.6 µm
a
259

Advertisement

Table of Contents
loading

Table of Contents