Siemens SIMOTICS T-1FW6 Series Configuration Manual page 284

High speed built-in torque motors
Hide thumbs Also See for SIMOTICS T-1FW6 Series:
Table of Contents

Advertisement

Coupled motors
10.3 Machine design and adjustment of the phase angle
1
2
3
4
5
6
Figure 10-1
The phase angles have been correctly adjusted if the following state is reached while the
axis is rotating in operation:
The reference marks of all rotors are always aligned at the same point in time with the
reference mark of the associated stator.
The machine design must ensure that this applies. You can achieve the required mechanical
adjustability of the mounting position, e.g. using an intermediate flange with elongated holes.
The angular tolerance is +/-1° mechanical.
The stator reference marks of electrically parallel-connected motors do not have to align with
one another.
The rotor reference marks do not have to align with one another.