The WS-X3003 10BaseF Expansion Module
The WS-X3003 10BaseF Expansion Module
The three-port 10BaseF expansion module (WS-X3003) is used for fiber-optic connections to
computers, hubs, servers, and other high-speed network devices. The 10BaseF expansion module is
shown in Figure 8.

Figure 8

LNK/FDX

Inserting the 10BaseF
Expansion modules are installed in the expansion slots on the front of the Catalyst switch. All front
expansion modules are installed in a similar way. Use the previous section "Installing The
WS-X3001 (100Base TX) Expansion Module" as an example for detailed installation instructions
and precautions for the 10BaseF module.
10BaseF Expansion Module Cables
The 10BaseF module's network ports are multimode fiber-optic interfaces with ST type connectors.
In full-duplex or half-duplex operating modes, the 10BaseF supports connection distances up to
2 km.
Connecting Cables to 10BaseF Expansion Module Ports
Enhanced versions of the Catalyst switch Stack support full-duplex operating mode. Unenhanced
versions of the Stack only support half-duplex operating mode. To set the half-duplex or full-duplex
mode, see Step 1 in the following cabling instructions.
Connect cables to the ST ports on the front of the 10BaseF module as follows:
Observe the following warnings and notes when cabling an expansion module with fiber-optic cable.
Warning
Warning

Step 1

Step 2
Step 3
12 Catalyst Matrix and Expansion Module Installation and Configuration Guide
The 10BaseF Expansion Module
XMIT
TX

RCV

DIAG
1
2
3
1
Laser radiation is present when the system is open.
Do not stare into the laser beam.
Determine if the unit is operating in half-duplex or full-duplex mode. The Catalyst switch
and the 10BaseF only operate in half-duplex mode for unenhanced Catalyst switch units.
Locate the desired DUPLEX switch for the port on the front of the module, and set it to the
appropriate position: down for half-duplex, or up for full-duplex. Set to half-duplex for
unenhanced Catalyst switch units.
Determine that you have the correct cable
Connect 10BaseF cables from a hub or end-node device to the ST ports on the front of the
10BaseF expansion module.
RX
TX
RX
TX
2
3
RX
DUPLEX
FULL
HALF
10Mb/s
1 2 3
WS-X3003