8 INSPECTION AND MAINTENANCE

Gauze Filter - Clean

Clean the gauze filter properly.
* A clogged gauze filter may result in insufficient
fuel supply, low power output, or engine stall
during operation.
When replacing the gauze filter,
tighten the new one under the same
condition as the old one was installed.
* If the tightening torque is too weak, fuel may
leak, causing a fire or fuel flow-out, which could
lead to environmental pollution.
• For the location of the fuel supply
pump, refer to
"2 ENGINE - OUTLINE"
(→ Page
73).
• Some parts such as joint and hose may
be outside the scope of our supply. For
the details, refer to such a document as
the specification sheet prepared by the
generator manufacturer.
• If it is not supplied by SME, follow the
instructions in the supplier's operation
manual.
146
Remove the banjo bolt at the inlet
1
port of the fuel feed pump.
• Tool: Wrench
Remove the gauze filter that is fitted
2
inside the banjo bolt.
• Tool: Flat blade screwdriver
Soak the gauze filter into fresh fuel
3
oil in the container, and wash it with
a soft brush or others.
• Replace the gauze filter with a new one, if it
has a break or deformation.
After cleaning, install the gauze filter
4
into the banjo bolt.
• Tool: Flat blade screwdriver
Mitsubishi Diesel Engine S16R & S16R2 OPERATION & MAINTENANCE MANUAL
Fig. 8-26 Banjo Bolt - Remove
Fig. 8-27 Gauze Filter - Remove
Pub. No. K29001-00320 Revision: 1