Status Codes - Prosense PQ Series Installation And User Manual

Hide thumbs Also See for PQ Series:
Table of Contents

Advertisement

Status Codes:

Fault
Code
Fault Text
0x00
NO FAULT
0x10
SENSOR ERROR
0x11
NOT CONNECTED
0x12
SIGNAL OUT RANGE
0x13
TEMPERATURE ERR
0x14
SENSOR_TYPE ERR
0x15
IR_LAMP_FRQ_ERR
0x16
SENSOR REG ERR
0x17
IR LAMP REG ERR
0x18
SENSOR SWITCHED OFF Pellistor sensor power off due to overrange for sensor protection
0x19
SENSOR REGULATOR
0x1A
SENSOR MODEL ERR
0x1B
SENSOR DATA CRC ERR
0x1C
NEGATIVE DRIFT
0x20
ADC ERR
0x21
INT ADC1 ERR
0x30
CURRENT OUTPUT ERR
0x31
DAC OUTPUT ERROR
0x32
LINE OUTPUT OPEN
0x33
LINE OUTPUT SHORT
0x40
SUPPLY VOL ERROR
0x41
LOW SUPPLY VOLTAGE
0x50
PRG RAM ERROR
0x51
RAM TEST FAILURE
0x52
STACK OVERFLOW ERR
0x60
PRG FLASH ERR
0x61
FLASH CRC ERR
0x62
CRC INIT ERR
0x63
XTRM STNGS CRC ERR
0x71
SETTINGS CRC ERR
0x72
ONE WIRE ERR
0x81
SENSOR CALIB DUE
0x82
BUMP TEST DUE
0x90
BATTERY ERROR
0x91
BATTERY VOLTAGE LOW Battery level is low
0x92
NO BATTERY DETECTED No battery is installed
0xa1
DSP COMMM ERR
0xa2
RS485 COMMM ERR
PRS-UM-PQ-EN-Rev.05-18.06.2020
OK
Sensor is in fault condition
Sensor is not connected or one-wire communication doesnot work.
Sensor signal is out of range
Temperature is out of range
Sensor type definiton read from sensor module does not match the recorded
configuration value
IR Timer error
Sensor power voltage error
IR sensor lamp regulator is in fault condition and does not generate lamp
feeding signal
Sensor regulator error, sensor power is not in defined range
Sensor model read from sensor module does not match the recorded
configuration value
Sensor Data corruption detected
Sensor signal is below defined minimum value
ADC circuit is not functioning correctly
Internal ADC1 signal level is not correct
Detector is not generating analogue output signal
MCU DAC output signal level is out of range
Analogue output is not connected
Analogue output is shorted
Power input is above maximum level
Power input is below minimum level
RAM fault detected
RAM test is failed
Stack Overflow Error
Flash error detected
Flash data corrupt
CRC calculation error
Main board parameter corruption
Parameter corruption
Main board and sensor board communication error
Defined calibration period is passed, calibraton needed
Defined bump test period is passed, bump test needed
Battery is in fault condition
Display communication failure
RS485 communication failure
Fault Description
49

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

PqdPqn

Table of Contents