Thermo Scientific Lindberg/Blue M Mini-Mite TF55030 Installation And Operating Manual page 47

Tube furnace
Table of Contents

Advertisement

| Main Controller: 1x8 & 5x16 Segment Programmable
Chapter 6
|
6-45
304243H02
8. To set the first Dwell, press SCROLL
or UP
button to set the value.
9. Now repeat the above three steps (6, 7 & 8) to set remaining all segments.
NOTE
If not all the segments are used for a program, the Ramp & Dwell of each of the
subsequent Segments should be set to OFF.
A program will end in one of two ways, either revert to the control Set Point or
dwell at the temperature set in the last segment used. When a program finishes
on a dwell and the dwell time expires the temperature will revert to the control set
point.
Before running a program ensure that the control set point is set to Zero to avoid
unexpected heating at the end of the program.
When a Holdback is set, each segment used must have a Ramp Rate assigned to
it, in order for it to be recognized by the program.
To Operate the Programmer
Operation
Action
To Run a program
Press and quickly
release
To Hold a program
Press and quickly
release
To Reset a program Press and hold
second
Programs can also be operated from the 'P.STAT' parameter found in the level 1
parameter list.
OR
button to select 'DWEL.1'. Press DOWN
Indication
Beacon RUN = On
Scrolling display - CURRENT
+
PROGRAM STATE
Beacon RUN = Flashing
Scrolling display - PROGRAM HOLD
+
If program has ended then
+
'PROGRAM END' will be displayed at
for more than 1
the end of the program