DOCUPRINT 4050, 4090, 4850, 4890, AND 92C IPS MESSAGES
3-14
F040
HCFR lost pitch reset.
There is a CPM, MIR, or HCFR board failure or a harness problem
between the CPM and MIR or the PHR and HFCR.
Action
Obtain and discard any purged output and press the [Continue]
button. If the error persists, contact your service representative.
F049
Sample tray transparency delivery contrary to selection.
You specified a destination for a transparency other than the sample
tray.
Action
Change the output configuration to specify the sample tray as the
destination, or do not use a transparency. (Refer to the Xerox
DocuPrint 4850/4890 or 92C IPS Guide to Configuring and Managing
the System.)
F059
Coronode AC voltage out of range.
There is a printer process control error.
Action
Press the [Continue] button. If the error persists, contact your service
representative.
F060
Charge dicorotron 2 voltage out of range.
There is a printer process control error.
Action
Press the [Continue] button. If the error persists, contact your service
representative.
F061
Transfer shield current out of range.
Indicates that the Transfer Dicorotron Shield current is out of range.
Action
Press the [Continue] button. If the error persists, contact your service
representative.
F062
Preclean shield current out of range.
There is a printer process control error.
Action
Press the [Continue] button. If the error persists, contact your service
representative.
F063
Developer bias voltage out of range.
There is a printer process control error.
Action
Press the [Continue] button. If the error persists, contact your service
representative.