Digital Outputs Parameters
PAR Description
u1
Utility managed by output K8 (0 = pump down valve; 1 = alarm)
u5
Cabinet temperature over which door heater OFF
u6
Switching on UV light for sterilization cycle duration
u7
Needle probe heating Temperature
u8
Maximum duration of needle probe heating
u9
Needle probe heating on open door (0 = no; 1 = yes)
u11
Utility managed by the output K7 (0 = cabinet light; 1 = UV light)
u12
Pump down valve deactivate delay from compressor off
Communication Parameters
PAR Description
L0
Reserved
L1
Recording interval during cycle
L2
Recording interval during store
LA
Device address
Baud rate
0 = 2,400 baud
Lb
1 = 4,800 baud
2 = 9,600 baud
3 = 19,200 baud
Parity
0 = none
LP
1 = odd
2 = even
Various Parameters
PAR Description
Keyboard lock function mode
0 = disable
E8
1 = Manual with permanent effect
2 = manual with temporary effect
E9
Splash Screen display from "off" status to the "
*Please contact Factory for more details on control setting
DATA LOGGING & INFORMATION RELATIVE TO HACCP ALARM FUNCTIONS
This control electronically logs data at all times when operating in the CHILL and Store Mode at a rate
of 1 to 240 minutes intervals that can defined by the parameters L1, L2. This log is accessible through
downloading information HACCP to view with your computer for printing and records.
48
Unit
Range
...
0, 1
°C/°F
-99 – 99
min
1 – 240
°C/°F
-99 – 199
min
1 – 240
...
0, 1
...
0, 1
Second
0 – 999
Unit
Range
...
...
Min
0 – 240
Min
0 – 240
...
1 – 247
247
...
0, 1, 2, 3
...
0, 1, 2, 3
Unit
Range
...
0, 1, 2
ºC
ºF
0
0
6
43
5
5
40
104
2
2
1
1
0
0
10
10
ºC
ºF
...
...
2
2
5
5
247
2
2
2
2
ºC
ºF
2
2

Hide quick links: