Blast Chiller Default List of configuration parameters
The following table illustrates the meaning of the configuration parameters.
PAR
Description
CA1
Cabinet probe offset
CA2
Need probe offset
CA3
Evaporator probe offset
CA4
Condensor probe offset
CA5
Needle probe offset 2
CA6
Needle probe offset 3
Probe type:
P0
0 = PTC
1 = NTC
Temperature unit of measurement
P2
0 = ºC
1 = ºF
Number of needle probe sensor
P3
0 = 0; 1 = 1; 2 = 2; 3 =3
P4
Enabling the evaporator probe
P5
Enabling condenser probe
Orientation of the display Visualization
P8
0 = device located at the top as the unit
1 = device located at the bottom as to the unit
Operation Parameters
PAR
Description
r0
Temperature differential (r7 – r12)
r1
Duration of Time-Controlled blast chilling
r2
Duration of Time-Controlled blast Freezing
r3
Temperature-controlled blast chilling & soft deep freezing temperature
r4
Temperature-controller deep freezing temp. (see also r6)
r5
Max duration of Temperature-controlled blast chilling (see also r3)
r6
Max duration of Temperature-controlled deep freezing (see also r4)
r7
Box temperature set-point for blast chilling & soft deep freezing
r8
Box Temperature setpoint during deep freezing (see also r0)
r9
Box Temperature setpoint during HARD blast chilling (see also r0)
r10
Box Temperature setpoint post blast chilling STORAGE (see also r0)
r11
Box Temperature setpoint post deep freezing STORAGE (see also r0)
r12
Box Temperature setpoint during Pre-Cooling (see also r0)
r13
Hard blast chilling end temperature setpoint (needle probe)
r14
Time-control hard blast chilling & Soft deep freezing
r15
Temperature below which count the max blast chilling & deep freezing
Type of operating cycle that can be selected
0 = blast chilling & Storage only
r16
1 = blast chilling & Storage or deep freezing & storage
2 = deep freezing & store only
Min temperature difference between needle probe and box temperature
r17
0 = Test will not be perform
r18
Duration of second phase test for correct insertion of needle probe
r19
Reserved
45
Unit
Range
ºC
°C/°F
-25 to 25
°C/°F
-25 to 25
°C/°F
-25 to 25
°C/°F
-25 to 25
°C/°F
-25 to 25
°C/°F
-25 to 25
...
0 / 1
...
0 / 1
...
0 / 3
...
0 / 1
...
0 / 1
...
0, 1
Unit
Range
ºC
°C/°F
1 – 15
5/7
Min
1 – 500
Min
1 – 500
240
°C/°F
-99 – 99
°C/°F
-99 – 99
-18
Min
1 – 500
Min
1 – 500
240
°C/°F
-99 – 99
°C/°F
-99 – 99
-26
°C/°F
-99 – 99
°C/°F
-99 – 99
°C/°F
-99 – 99
-18
°C/°F
-99 – 99
°C/°F
-99 – 99
%
10 – 100
°C/°F
-99 – 99
...
0 – 2
0 / 2
°C/°F
0 – 99
Second
1 – 99
...
...
ºF
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
3
3
1
1
0
0
1
1
ºF
5/7
90
90
240
3
37
0
90
90
240
0
32
-15
-4
25
2
36
0
5
41
15
59
60
60
65
149
0 / 2
5
5
60
60
...
...