Master Bilt MCR-33101 Installation & Operation Instructions page 32

Blast chiller
Hide thumbs Also See for MCR-33101:
Table of Contents

Advertisement

A1 – Temperature-controlled blast chilling & storage.
The temperature-controlled blast chilling and storage cycle is divided into the following two phases:
- Blast chilling
- Storage.
Operate as indicated to start the cycle:
1. Make sure the device is in the "on" HOME status.
2. Make sure that the keyboard is not locked and that no
procedure is in progress.
3. Press and release the key (1) press and release the key
(2) and then press and release the key (3).the device
will display the blast chilling end temperature and the
work set-point during blast chilling.
4. Press and release the MENU key and then press and
release the key UP or the key DOWN to select the
blast chilling end temperature and the work set-point
during blast chilling.
4.1 Press and release (+) key or the (-) key to modify
these values and then the ESCAPE key to memorize
them; these values can also be memorized through
parameters r3 and r7 in program parameter mode.
5. Press and release the START/STOP key (1): the test
to verify the correct insertion of the needle probe will
be started.
5.1 If the test is completed successfully, the cycle will be started
5.2 If the test is not completed successfully, the buzzer will be activated for 5 s every 60 s and the cycle
will be started with timed-control.
During blast chilling the device displays the temperature detected by the needle probe, the cabinet
temperature, the program name (if named) and the time passed since the start of blast chilling.
If the temperature detected by the needle probe reaches
the blast chilling end temperature within the maximum
blast chilling duration, it means that blast chilling has
been completed successfully, the device will
automatically pass to storage and the buzzer will be
activated to indicate that the cycle has completed.
If the temperature detected by the needle probe does not
reach the blast chilling end temperature within the
maximum blast chilling duration, blast chilling will not
be completed successfully but it will continue and the
buzzer will be activated. When temperature detected by the needle probe reaches the blast chilling end
temperature; the device automatically passes to storage in the same way as illustrated previously.
** The system can be stopped at any time during the cycle - press and release the START/STOP KEY
32